LBC Manufacturing is proud to add the NSF approved Liquid Chlorinator to the market.  The need for an alternate way of chlorination, that is certified to NSF/ANSI standard 46 by NSF INTERNATIONAL , is a necessary step to controlling the quality that all homeowners expect and deserve.

LBC Manufacturing recommends installation by TCEQ licensed and trained installers!

1. Locate the aerobic System Holding/Pump Tank
2. Place the Liquid chlorinator housing on a level undisturbed base. This may be accommplished many ways, just ensure choice location does not allow the chlorinator base to move from its installed position. additionally, the housing lid must be above final installation grade.
3. Obtain 20 linear feet of 4 inch PVC pipe and a 4 inch End Cap
4.Using PVC cleaner and glue, attach 20 feet of 4 inch pipe to the chlorinator housing.
5. Next, glue the 4 inch End Cap to the remaining end of the 20 ft length of pipe
6. Next, locate the poly vinyl tubing and route into the holding/pump tank ( The vinly tubing is flexable and subject to damage from sharp or heavy objects. It is prefferred to install the tubing in a sleeve to help protect from damage.
7. Locate the sprinkler pump plumbing located inside the pump tank. Install the venturi onto the sprinkler pump plumbing. ( Tank Plumbing techniques vary, just ensure the venturi has a water tight seal.  Proper operation of the venturi requires 20 psi from the sprinkler pump)
8.Locate the poly vinyl tubing previously routed into holding/pump tank. Connect the end of the tubing to the venturi suction port.
9. Next, Remove the Chlorinator Housing lid and fill the housing with twelve gallons of 6% Sodium Hypochlorite (Household Bleach)
10. Finally, Engage the sprinkler pump and ensure the Liquid Bleach Chlorinator is visibly moving bleach through the vinyl tubing.
**If bleach is not visibly moving through the poly vinyl tubing, refer to the troubleshooting section.**

lbc500diagram.jpg

diagram.jpg
DIAGRAM OF INSTALLER'S MODEL

*Fill with common HOUSEHOLD BLEACH(6% sodium hypochlorite)
*Very Simple Installation and virtually
MAINTENANCE FREE
*Great for new installations or RETROFITTING any existing pump tank
*LOWER annual OPERATING COST

***THE ONLY PROVEN METHOD FOR MAINTENANCE-FREE DISINFECTION

Contact Us